| BATTERY CHARGER ONLINE TECHNICAL BINDER Product Operating Manuals |
[DOCUMENTATION UPDATE HISTORY] [CUSTOM DRAWINGS]
Updated: Thursday, May 18, 2006 (view updates)
STANDARD DOCUMENT TYPE ____________________ |
|
![]() ELECTRICAL CONTROL DRAWINGS |
|
|
![]() SALES BROCHURE |
![]() ORDERING WORKSHEET |
|
PRODUCT LINE |
||||||
| AT10.1 SERIES (Group I - 1PH input) |
JA5011-01 (6-25 Adc) |
ELECTRICAL DWGs |
OUTLINE DWGs |
INTERNAL DWGs |
JF5006-00 | JF5021-01 |
| AT10.1 SERIES (Group II - 1PH input) |
JA5011-02 (30-100 Adc) |
ELECTRICAL DWGs |
OUTLINE DWGs |
INTERNAL DWGs |
JF5006-00 | JF5021-02 |
|
AT30 SERIES (3PH input) |
JA5011-03 (25-1,000 Adc) |
ELECTRICAL DWGs |
OUTLINE DWGs |
INTERNAL DWGs |
JF5018-00 | JF5021-03 |
|
AT SERIES COMMUNICATIONS PCB |
JA5011-04 | JE5107-00 | n/a | JE5107-00 | JF5014-00 | see AT Series chargers above |
|
AT SERIES ACCESSORIES |
AT
SERIES ACCESSORIES DOCUMENT MATRIX |
JF5020-00 | see AT Series chargers above |
|||
| SCR/SCRF SERIES SINGLE PHASE INPUT |
JA5009-00 |
ELECTRICAL DWGs |
OUTLINE DWGs |
INTERNAL DWGs |
JF5010-00 | JF0026-00 |
| SCR/SCRF SERIES THREE PHASE INPUT |
ELECTRICAL DWGs |
OUTLINE DWGs |
INTERNAL DWGs |
JF5010-00 | JF0026-00 | |
| UMC UNIVERSAL MAINTENANCE CHARGER |
JA5041-01 | COMPLETE DRAWING MATRIX |
JF5008-00 | JF5031-00 | ||
| RMC RAILROAD MAINTENANCE CHARGER |
JA5041-02 manual insert |
COMPLETE DRAWING MATRIX |
JF5015-00 | JF5031-00 | ||
| SINGLE-CELL PORTABLE CHARGER |
JA5041-03 | COMPLETE DRAWING MATRIX |
JF5007-00 | JF5031-00 | ||
|
TBC DC DISTRIBUTION PANEL |
JA5041-04 | COMPLETE DRAWING MATRIX |
JF5023-00 | JF5031-00 | ||
|
a full Customized
Record Drawing Package for |
![]() |
AT10.1 SERIES BATTERY CHARGER
SINGLE PHASE INPUT - MICROPROCESSOR CONTROLLED
GROUP I (6-25 Adc OUTPUT)
ELECTRICAL / CONTROL DRAWINGS
| INSTRUMENT PANEL / PC BOARD DETAIL |
MAINFRAME SCHEMATIC |
CONNECTION DIAGRAM |
| JE5030-10 STANDARD W/O OPTIONS |
JE5031-00 STANDARD W/O OPTIONS |
JE5033-00 STANDARD W/O OPTIONS |
| JE5030-19 W/AUXILIARY ALARM RELAY BOARD OPTION |
JE5031-99 WITH MAJORITY OF COMMON OPTIONS |
JE5033-99 WITH MAJORITY OF COMMON OPTIONS |
Note: As of July 2004, the rectifier assembly for the
AT10.1 Group I battery charger has been upgraded.
Please see our news section for details of this change. The online electrical /
control drawings listed above
reflect the current configuration of the AT10.1 Group I battery charger with this new
assembly. If you are
interested in obtaining standard drawings for an AT10.1 Group I battery charger shipped prior to
this date,
please contact Michael C. Rupprecht.
Legacy documentation for the AT10.1 Series battery charger
is always available for all configurations of this charger line, dating back to
its introduction
in early 1996.
[TOP]
AT10.1 SERIES BATTERY CHARGER
SINGLE PHASE INPUT - MICROPROCESSOR CONTROLLED
GROUP I (6-25 Adc OUTPUT)
ENCLOSURE OUTLINE DRAWINGS (NEMA-1 / IP20 TYPE)
| GROUP I AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| 6 Adc | JE5023-00 | JE5023-00 | JE5023-00 | JE5023-00 |
| 12 Adc | JE5023-00 | JE5023-00 | JE5023-00 | JE5024-00 |
| 16 Adc | JE5023-00 | JE5023-00 | JE5024-00 | JE5024-00 |
| 20 Adc | JE5023-00 | JE5023-00 | JE5024-00 | JE5024-00 |
| 25 Adc | JE5023-00 | JE5023-00 | JE5024-00 | JE5024-00 |
| * NOTE: GROUP I AT10.1 SERIES BATTERY CHARGERS FEATURE AN ADDITIONAL PENTHOUSE ENCLOSURE WHEN CERTAIN OPTIONS ARE SUPPLIED (e.g. AUXILIARY ALARM RELAY PC BOARD, 480 Vac INPUT, MED/HI AIC CIRCUIT BREAKERS, etc.) PLEASE USE THE PRECEDING DRAWINGS WITH THE "-01" EXTENSION IF APPLICABLE. |
||||
| W/PENTHOUSE | JE5023-01 * | JE5024-01 * | ||
ENCLOSURE OUTLINE DRAWINGS (NEMA-4/12/13 / IP5x TYPE)
AT10.1 SERIES GROUP I BATTERY CHARGERS ARE AVAILABLE
HOUSED IN A SPECIAL NEMA-4/12/13 TYPE ENCLOSURE. PLEASE REFER
TO THE FOLLOWING OUTLINE DRAWING (JE5068-00)
FOR DETAILS.
[TOP]
AT10.1 SERIES BATTERY
CHARGER
SINGLE PHASE INPUT - MICROPROCESSOR CONTROLLED
GROUP I (6-25 Adc OUTPUT)
INTERNAL COMPONENT LAYOUT DRAWINGS
| GROUP I AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| 6 Adc | JE5027-00 | JE5027-00 | JE5027-00 | JE5027-00 |
| 12 Adc | JE5027-00 | JE5027-00 | JE5027-00 | JE5027-00 |
| 16 Adc | JE5027-00 | JE5027-00 | JE5027-00 | JE5027-00 |
| 20 Adc | JE5027-00 | JE5027-00 | JE5027-00 | JE5027-00 |
| 25 Adc | JE5027-00 | JE5027-00 | JE5027-00 | JE5027-00 |
|
NOTE: THESE AT10.1 SERIES INTERNAL
COMPONENT |
||||
| AT10.1 GROUP I | JE5027-99 ** | |||
DRAWINGS REVISED 10-08-2004
Note: As of July 2004, the rectifier assembly for the
AT10.1 Group I battery charger has been upgraded.
Please see our news section for details of this change. The online internal component
layout drawings listed
above reflect the current configuration of the AT10.1 Group I battery charger with this new
assembly. If
you are interested in obtaining standard drawings for an AT10.1 Group I battery charger shipped prior to
this date, please contact Michael C. Rupprecht.
Legacy documentation for the AT10.1 Series battery charger
is always available for all configurations of this charger line, dating back to its introduction
in early 1996.
[TOP]
AT10.1 SERIES BATTERY CHARGER
SINGLE PHASE INPUT - MICROPROCESSOR CONTROLLED
GROUP II (30-100 Adc OUTPUT)
ELECTRICAL / CONTROL DRAWINGS
| INSTRUMENT PANEL / PC BOARD DETAIL |
MAINFRAME SCHEMATIC |
CONNECTION DIAGRAM |
| JE5030-20 STANDARD W/O OPTIONS |
JE5032-00 STANDARD W/O OPTIONS |
JE5034-00 STANDARD W/O OPTIONS |
| JE5030-29 W/AUXILIARY ALARM RELAY BOARD OPTION |
JE5032-99 WITH MAJORITY OF COMMON OPTIONS |
JE5034-99 WITH MAJORITY OF COMMON OPTIONS |
[TOP]
AT10.1 SERIES BATTERY CHARGER
SINGLE PHASE INPUT - MICROPROCESSOR CONTROLLED
GROUP II (30-100 Adc OUTPUT)
ENCLOSURE OUTLINE DRAWINGS (NEMA-1 / IP20 TYPE)
| GROUP II AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| 30 Adc | JE5025-00 | JE5025-00 | JE5025-00 | JE5025-00 |
| 40 Adc | JE5025-00 | JE5025-00 | JE5025-00 | JE5026-00 |
| 50 Adc | JE5025-00 | JE5025-00 | JE5025-00 | JE5026-00 |
| 75 Adc | JE5026-00 | JE5026-00 | JE5026-00 | JE5026-00 |
| 100 Adc | JE5026-00 | JE5026-00 | JE5026-00 | N/A |
ENCLOSURE OUTLINE DRAWINGS (NEMA-4/12/13 / IP5x TYPE)
AT10.1 SERIES GROUP I I BATTERY CHARGERS
ARE AVAILABLE
HOUSED IN SPECIAL NEMA-4/12/13 TYPE ENCLOSURES. PLEASE
REFER TO THE FOLLOWING OUTLINE DRAWINGS FOR DETAILS.
| GROUP II AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| 30 Adc | JE5073-00 | JE5073-00 | JE5073-00 | JE5073-00 |
| 40 Adc | JE5073-00 | JE5073-00 | JE5073-00 | JE5074-00 |
| 50 Adc | JE5073-00 | JE5073-00 | JE5073-00 | JE5074-00 |
| 75 Adc | JE5074-00 | JE5074-00 | JE5074-00 | JE5074-00 |
| 100 Adc | JE5074-00 | JE5074-00 | JE5074-00 | N/A |
[TOP]
AT10.1 SERIES BATTERY
CHARGER
SINGLE PHASE INPUT - MICROPROCESSOR CONTROLLED
GROUP II (30-100 Adc OUTPUT)
INTERNAL COMPONENT LAYOUT DRAWINGS
| GROUP II AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| 30 Adc | JE5028-00 | JE5028-00 | JE5028-00 | JE5028-00 |
| 40 Adc | JE5028-00 | JE5028-00 | JE5028-00 | JE5029-00 |
| 50 Adc | JE5028-00 | JE5028-00 | JE5028-00 | JE5029-00 |
| 75 Adc | JE5029-00 | JE5029-00 | JE5029-00 | JE5029-00 |
| 100 Adc | JE5029-00 | JE5029-00 | JE5029-00 | N/A |
|
NOTE: THESE AT10.1 SERIES INTERNAL
COMPONENT |
||||
| AT10.1 GROUP II | JE5028-99 ** | JE5029-99 ** | ||
[TOP]
AT30 SERIES BATTERY CHARGER
THREE PHASE INPUT - MICROPROCESSOR CONTROLLED
(25-1,000 Adc OUTPUT)
ELECTRICAL / CONTROL DRAWINGS
| INSTRUMENT PANEL / PC BOARD DETAIL |
MAINFRAME SCHEMATIC |
CONNECTION DIAGRAM |
| JE5091-30 STANDARD W/O OPTIONS |
JE5092-00 STANDARD W/O OPTIONS |
SEE NOTE BELOW OR (REQUEST) |
| JE5091-39 W/AUXILIARY ALARM RELAY BOARD OPTION |
JE5092-99 WITH MAJORITY OF COMMON OPTIONS |
SEE NOTE BELOW OR (REQUEST) |
| Note: Standard connection (wiring) diagrams for all ratings
and configurations of the AT30 Series Battery Charger are not available. In lieu of these documents please reference the following: 1) review the available electrical schematics (JE5092-00
/ JE5092-99)
to familiarize 2) review the available internal component layout drawings
to identify the physical 3) review the standard AT30 wire list (EH5027-00)
which lists every power and If this procedure does not meet your needs, a custom
connection diagram is available upon request, |
[TOP]
AT30 SERIES BATTERY CHARGER
THREE PHASE INPUT - MICROPROCESSOR CONTROLLED
(25-1,000 Adc OUTPUT)
ENCLOSURE OUTLINE DRAWINGS (NEMA-1 / IP20 TYPE)
| AT30 AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| 25 Adc | N/A | N/A | N/A | JE5085-00 |
| 30 Adc | N/A | N/A | N/A | JE5085-00 |
| 40 Adc | N/A | N/A | N/A | JE5085-00 |
| 50 Adc | JE5085-00 | JE5085-00 | JE5085-00 | JE5085-00 |
| 75 Adc | JE5085-00 | JE5085-00 | JE5085-00 | JE5085-00 |
| 100 Adc | JE5085-00 | JE5085-00 | JE5085-00 | JE5086-00 |
| 125 Adc | JE5086-00 | JE5086-00 | JE5086-00 | JE5086-00 |
| 150 Adc | JE5086-00 | JE5086-00 | JE5086-00 | JE5086-00 |
| 200 Adc | JE5086-00 | JE5086-00 | JE5086-00 | JE5086-00 |
| 250 Adc | JE5086-00 | JE5086-00 | JE5086-00 | JE5095-00 * |
| 300 Adc | JE5086-00 | JE5086-00 | JE5086-00 | JE5095-00 * |
| 400 Adc | N/A | JE5095-00 | JE5095-00 * | JE5095-00 * |
| 500 Adc | N/A | JE5095-00 | JE5095-00 * | JE5096-00 * |
| 600 Adc | N/A | JE5095-00 | JE5096-00 * | JE5096-00 * |
| 800 Adc | N/A | JE5096-00 * | JE5096-00 * | JE5096-00 * |
| 1,000 Adc | N/A | JE5096-00 * | JE5096-00 * | JE5096-00 * |
| AT30 AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
|
* NOTE: STYLE-163 (JE5095-00)
AND STYLE-198 (JE5096-00)
AT30 |
||||
ENCLOSURE OUTLINE DRAWINGS (NEMA-4/12/13 / IP5x TYPE)
AT30 SERIES BATTERY CHARGERS
ARE AVAILABLE HOUSED IN SPECIAL
NEMA-4/12/13 TYPE ENCLOSURES. PLEASE REFER TO THE TABLES ABOVE
AND SELECT THE CORRESPONDING OUTLINE DRAWING BELOW FOR DETAILS.
| AT30 NEMA-1/IP20 ENCLOSURE TYPE (see above rating) |
STANDARD NEMA-1 / IP20 OUTLINE DRAWING |
CORRESPONDING NEMA-4/12/13 / IP5x OUTLINE DRAWING |
| STYLE-5018 | JE5085-00 | JE5074-00 |
| STYLE-5030 | JE5086-00 | JE5108-00 |
| STYLE-163 | JE5095-00 | (REQUEST) * |
| STYLE-198 | JE5096-00 | (REQUEST) * |
* Note: Standard NEMA-4/12/13 enclosure outline
drawings for AT30 Series Battery Charger
models normally supplied in Style-163 and Style-198 NEMA-1 enclosures are not available
at this
time. For a custom quote, please contact Michael C. Rupprecht
for drawings not listed above.
[TOP]
AT30 SERIES BATTERY CHARGER
THREE PHASE INPUT - MICROPROCESSOR CONTROLLED
(25-1,000 Adc OUTPUT)
INTERNAL COMPONENT LAYOUT DRAWINGS
| AT30 AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| 25 Adc | N/A | N/A | N/A | JE5088-00 |
| 30 Adc | N/A | N/A | N/A | JE5088-00 |
| 40 Adc | N/A | N/A | N/A | JE5088-00 |
| 50 Adc | JE5088-00 | JE5088-00 | JE5088-00 | JE5088-00 |
| 75 Adc | JE5088-00 | JE5088-00 | JE5088-00 | JE5088-00 |
| 100 Adc | JE5088-00 | JE5088-00 | JE5088-00 | JE5089-00 |
| 125 Adc | JE5089-00 | JE5089-00 | JE5089-00 | JE5089-00 |
| 150 Adc | JE5089-00 | JE5089-00 | JE5089-00 | JE5089-00 |
| 200 Adc | JE5089-00 | JE5089-00 | JE5089-00 | JE5089-00 |
| 250 Adc | JE5089-00 | JE5089-00 | JE5089-00 | JE5098-00 |
| 300 Adc | JE5089-00 | JE5089-00 | JE5089-00 | JE5098-00 |
| 400 Adc | N/A | JE5098-00 | JE5098-00 | JE5098-00 |
| 500 Adc | N/A | JE5098-00 | JE5098-00 | (REQUEST) * |
| 600 Adc | N/A | JE5098-00 | (REQUEST) * | (REQUEST) * |
| 800 Adc | N/A | (REQUEST) * | (REQUEST) * | (REQUEST) * |
| 1,000 Adc | N/A | (REQUEST) * | (REQUEST) * | (REQUEST) * |
| AT30 AMPERE RATING |
12 Vdc | 24 Vdc | 48 Vdc | 130 Vdc |
| NOTE: THESE AT30 SERIES INTERNAL
COMPONENT LAYOUT DRAWINGS FEATURE ONLY STANDARD COMPONENTS, AND MAY NOT REPRESENT YOUR SPECIFIC UNIT. PLEASE USE THE FOLLOWING DRAWINGS WITH THE "-99" EXTENSION TO VIEW SIMILAR INTERNAL COMPONENT LAYOUT DRAWINGS FEATURING ALL AVAILABLE OPTIONS. |
||||
| AT30 | JE5088-99 | JE5089-99 | JE5098-99 | (REQUEST) * |
* Note: Standard internal component layout drawings for AT30 Series Battery Charger
models
normally supplied in Style-198 enclosures are not available at this time.
For a custom quote, please
contact Michael C. Rupprecht
for drawings not listed
above.
[TOP]
AT10.1/AT30 SERIES BATTERY CHARGER ACCESSORIES
STANDARD DOCUMENT TYPE ____________________ |
|
![]() ELECTRICAL CONTROL DRAWINGS |
|
|
![]() SALES BROCHURE |
|
PRODUCT LINE |
|||||
|
AT SERIES COMMUNICATIONS PCB |
JA5011-04 | JE5107-00 | n/a | JE5107-00 | JF5014-00 |
|
AT SERIES FORCED LOAD SHARING |
JA5054-00 |
coming soon |
n/a |
coming soon |
coming soon |
| AT-DC DISTRIBUTION PANEL |
JA5011-05 |
coming soon |
coming soon |
coming soon |
JF5032-00 |
MORE AT SERIES ACCESSORY
DRAWINGS & DOCUMENTATION COMING SOON...
Note: Standard drawings for all AT Series Accessory
Items available in Sales Brochure
JF5020-00 are not available at this time.
We will be posting these shortly. Please contact
Michael C. Rupprecht for specific
document/drawing requests.
[TOP]
SCR/SCRF SERIES BATTERY CHARGERS
SINGLE PHASE INPUT
ELECTRICAL / CONTROL DRAWINGS
| INSTRUMENT PANEL DETAIL |
MAINFRAME SCHEMATIC |
CONNECTION DIAGRAM |
| JE0260-00 STANDARD (W/O OPTIONS) |
JE5076-00 STANDARD (W/O OPTIONS) |
STANDARD (W/O OPTIONS) (REQUEST) |
| JE0260-37 W/COMBINED ALARM STATUS MONITOR (CASM) OPTION |
JE5077-00 W/COMBINED ALARM STATUS MONITOR (CASM) OPTION |
W/ COMBINED ALARM STATUS MONITOR (CASM) OPTION (REQUEST) |
| JE0260-99 WITH MAJORITY OF COMMON OPTIONS |
CUSTOM SCHEMATIC |
CUSTOM CONNECTION DIAGRAM |
Note: Standard connection diagrams for the SCR/SCRF
Series Battery Charger are not available
at this time. Please contact Michael C. Rupprecht with any documentation request.
[TOP]
SCR/SCRF SERIES BATTERY CHARGERS
SINGLE PHASE INPUT
ENCLOSURE OUTLINE DRAWINGS
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
||
| 6 Adc | JE0460-01 | JE0460-01 | JE0460-01 | JE0461-01 | JE0462-01 | 6 Adc |
| 12 Adc | JE0460-01 | JE0460-01 | JE0460-01 | JE0461-01 | N/A | 12 Adc |
| 16 Adc | JE0460-01 | JE0460-01 | JE0461-01 | JE0461-01 | JE0462-01 | 16 Adc |
| 20 Adc | JE0460-01 | JE0460-01 | JE0461-01 | JE0461-01 | N/A | 20 Adc |
| 25 Adc | JE0461-01 | JE0461-01 | JE0461-01 | JE0461-01 | JE0463-01 | 25 Adc |
| 30 Adc | JE0461-01 | JE0461-01 | JE0461-01 | JE0461-01 | N/A | 30 Adc |
| 35 Adc | JE0461-01 | JE0461-01 | JE0461-01 | JE0462-01 | N/A | 35 Adc |
| 40 Adc | JE0461-01 | JE0461-01 | JE0461-01 | JE0462-01 | N/A | 40 Adc |
| 50 Adc | JE0461-01 | JE0461-01 | JE0462-01 | JE0462-01 | N/A | 50 Adc |
| 60 Adc | JE0462-01 | JE0462-01 | JE0462-01 | N/A | N/A | 60 Adc |
| 75 Adc | JE0462-01 | JE0462-01 | JE0462-01 | JE0463-01 | N/A | 75 Adc |
| 100 Adc | JE0463-01 | JE0463-01 | JE0463-01 | N/A | N/A | 100 Adc |
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
[TOP]
SCR/SCRF SERIES BATTERY CHARGERS
SINGLE PHASE INPUT
INTERNAL COMPONENT LAYOUT DRAWINGS
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
||
| 6 Adc | JE0240-00 | JE0240-00 | JE0240-00 | JE0241-00 | JE0242-01 | 6 Adc |
| 12 Adc | JE0240-00 | JE0240-00 | JE0240-00 | JE0241-00 | N/A | 12 Adc |
| 16 Adc | JE0240-00 | JE0240-00 | JE0241-00 | JE0241-00 | JE0242-01 | 16 Adc |
| 20 Adc | JE0240-00 | JE0240-00 | JE0241-00 | JE0241-00 | N/A | 20 Adc |
| 25 Adc | JE0241-00 | JE0241-00 | JE0241-00 | JE0241-00 | JE0243-01 | 25 Adc |
| 30 Adc | JE0241-00 | JE0241-00 | JE0241-00 | JE0241-00 | N/A | 30 Adc |
| 35 Adc | JE0241-00 | JE0241-00 | JE0241-00 | JE0242-01 | N/A | 35 Adc |
| 40 Adc | JE0241-00 | JE0241-00 | JE0241-00 | JE0242-01 | N/A | 40 Adc |
| 50 Adc | JE0241-00 | JE0241-00 | JE0242-01 | JE0242-01 | N/A | 50 Adc |
| 60 Adc | JE0242-01 | JE0242-01 | JE0242-01 | N/A | N/A | 60 Adc |
| 75 Adc | JE0242-01 | JE0242-01 | JE0242-01 | JE0243-01 | N/A | 75 Adc |
|
100 Adc |
JE0243-01 | JE0243-01 | JE0243-01 | N/A | N/A | 100 Adc |
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
[TOP]
SCR/SCRF SERIES BATTERY CHARGERS
THREE PHASE INPUT
ELECTRICAL / CONTROL DRAWINGS
| INSTRUMENT PANEL DETAIL |
MAINFRAME SCHEMATIC |
CONNECTION DIAGRAM |
| JE0260-00 STANDARD (W/O OPTIONS) |
JE5078-00 STANDARD (W/O OPTIONS) |
STANDARD (W/O OPTIONS) (REQUEST) |
| JE0260-37 W/COMBINED ALARM STATUS MONITOR (CASM) OPTION |
JE5079-00 W/COMBINED ALARM STATUS MONITOR (CASM) OPTION |
W/ COMBINED ALARM STATUS MONITOR (CASM) OPTION (REQUEST) |
| JE0260-99 WITH MAJORITY OF COMMON OPTIONS |
CUSTOM SCHEMATIC |
CUSTOM CONNECTION DIAGRAM |
Note: Standard connection diagrams for the SCR/SCRF
Series Battery Charger are not available
at this time.
Please contact Michael C. Rupprecht with any documentation request.
[TOP]
SCR/SCRF SERIES BATTERY CHARGERS
THREE PHASE INPUT
ENCLOSURE OUTLINE DRAWINGS
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
||
| 16 Adc | N/A | N/A | N/A | N/A | JE0462-03 | 16 Adc |
| 20 Adc | N/A | N/A | N/A | N/A | N/A | 20 Adc |
| 25 Adc | N/A | N/A | N/A | JE0462-03 | JE0463-03 | 25 Adc |
| 30 Adc | N/A | N/A | N/A | JE0462-03 | N/A | 30 Adc |
| 35 Adc | N/A | N/A | N/A | JE0462-03 | JE0463-03 | 35 Adc |
| 40 Adc | N/A | N/A | N/A | JE0462-03 | N/A | 40 Adc |
| 50 Adc | N/A | JE0462-03 | JE0462-03 | JE0463-03 | JE0463-03 | 50 Adc |
| 60 Adc | JE0462-03 | JE0462-03 | JE0462-03 | JE0463-03 | N/A | 60 Adc |
| 75 Adc | JE0462-03 | JE0462-03 | JE0462-03 | JE0463-03 | JE0464-03 | 75 Adc |
| 100 Adc | JE0463-03 | JE0463-03 | JE0463-03 | JE0463-03 | JE0464-03 | 100 Adc |
| 125 Adc | JE0463-03 | JE0463-03 | JE0463-03 | JE0463-03 | N/A | 125 Adc |
| 150 Adc | N/A | JE0463-03 | JE0463-03 | JE0464-03 | JE0465-03 | 150 Adc |
| 175 Adc | N/A | JE0463-03 | JE0463-03 | JE0464-03 | N/A | 175 Adc |
| 200 Adc | N/A | JE0463-03 | JE0463-03 | JE0464-03 | JE0465-03 | 200 Adc |
| 250 Adc | N/A | JE0464-03 | JE0464-03 | JE0464-03 | N/A | 250 Adc |
| 300 Adc | N/A | JE0464-03 | JE0464-03 | JE0465-03 | JE0465-03 | 300 Adc |
| 400 Adc | N/A | JE0464-03 | JE0464-03 | JE0465-03 | N/A | 400 Adc |
| 500 Adc | N/A | JE0464-03 | JE0465-03 | JE0465-03 | N/A | 500 Adc |
| 600 Adc | N/A | JE0464-03 | JE0465-03 | JE0465-03 | N/A | 600 Adc |
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
[TOP]
SCR/SCRF SERIES BATTERY CHARGERS
THREE PHASE INPUT
INTERNAL COMPONENT LAYOUT DRAWINGS
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
||
| 16 Adc | N/A | N/A | N/A | N/A | JE0242-03 | 16 Adc |
| 20 Adc | N/A | N/A | N/A | N/A | N/A | 20 Adc |
| 25 Adc | N/A | N/A | N/A | JE0242-03 | JE0243-03 | 25 Adc |
| 30 Adc | N/A | N/A | N/A | JE0242-03 | N/A | 30 Adc |
| 35 Adc | N/A | N/A | N/A | JE0242-03 | JE0243-03 | 35 Adc |
| 40 Adc | N/A | N/A | N/A | JE0242-03 | N/A | 40 Adc |
| 50 Adc | N/A | JE0242-03 | JE0242-03 | JE0243-03 | JE0243-03 | 50 Adc |
| 60 Adc | JE0242-03 | JE0242-03 | JE0242-03 | JE0243-03 | N/A | 60 Adc |
| 75 Adc | JE0242-03 | JE0242-03 | JE0243-03 | JE0243-03 | JE0244-00 | 75 Adc |
| 100 Adc | JE0243-03 | JE0243-03 | JE0243-03 | JE0243-03 | JE0244-00 | 100 Adc |
| 125 Adc | JE0243-03 | JE0243-03 | JE0243-03 | JE0243-03 | N/A | 125 Adc |
| 150 Adc | N/A | JE0243-03 | JE0243-03 | JE0244-00 | JE0245-00 | 150 Adc |
| 175 Adc | N/A | JE0243-03 | JE0243-03 | JE0244-00 | N/A | 175 Adc |
| 200 Adc | N/A | JE0243-03 | JE0243-03 | JE0244-00 | JE0245-00 | 200 Adc |
| 250 Adc | N/A | JE0244-00 | JE0244-00 | JE0244-00 | N/A | 250 Adc |
| 300 Adc | N/A | JE0244-00 | JE0244-00 | JE0245-00 | JE0245-00 | 300 Adc |
| 400 Adc | N/A | JE0244-00 | JE0244-00 | JE0245-00 | N/A | 400 Adc |
| 500 Adc | N/A | JE0244-00 | JE0245-00 | JE0245-00 | N/A | 500 Adc |
| 600 Adc | N/A | JE0244-00 | JE0245-00 | JE0245-00 | N/A | 600 Adc |
|
12 Vdc |
24 Vdc OUTPUT |
48 Vdc OUTPUT |
130 Vdc OUTPUT |
260 Vdc OUTPUT |
[TOP]
UNIVERSAL MAINTENANCE CHARGER (UMC)
DRAWING MATRIX
(newly updated
to Rev. 2 configuration on 05/16/2006)
| 10-25 Adc OUTPUT | 10-50 Adc OUTPUT |
| DRAWING LIST JE5035-25 |
DRAWING LIST JE5035-50 |
|
ENCLOSURE OUTLINE JE5036-25 |
ENCLOSURE OUTLINE JE5036-50 |
|
INTERNAL COMPONENT LAYOUT JE5037-25 |
INTERNAL COMPONENT LAYOUT JE5037-50 |
|
INSTRUMENT PANEL DETAIL JE5038-25 |
INSTRUMENT PANEL DETAIL JE5038-50 |
|
ELECTRICAL SCHEMATIC JE5039-25 |
ELECTRICAL SCHEMATIC JE5039-50 |
|
CONNECTION DIAGRAM JE5040-25 |
CONNECTION DIAGRAM JE5040-50 |
[TOP]
RAILROAD MAINTENANCE CHARGER (RMC)
DRAWING MATRIX
| DWG LIST / NAMEPLATE JE5050-00 |
INSTRUMENT PANEL DETAIL JE5053-00 |
|
ENCLOSURE OUTLINE JE5051-00 |
ELECTRICAL SCHEMATIC JE5054-00 |
|
INTERNAL COMPONENT LAYOUT JE5052-00 |
CONNECTION DIAGRAM JE5055-00 |
[TOP]
DRAWING MATRIX
[TOP]
TRANSIT BATTERY
CHARGING (TBC)
DC DISTRIBUTION PANEL
DRAWING MATRIX
|
ENCLOSURE OUTLINE JE5069-04 |
ELECTRICAL SCHEMATIC JE5071-00 |
|
INTERNAL COMPONENT LAYOUT COMING SOON (REQUEST) |
CONNECTION DIAGRAM COMING SOON (REQUEST) |
Note: Standard internal component layout drawings and
connection diagrams for the Transit Battery Charging
DC Distribution Panel are not available at this time. However, custom
drawings are available for free upon
request, based upon any quote. Please contact Michael C. Rupprecht
with specifications for the
Transit Battery Charging system in question. Thank you for your
attention.
[TOP]